Siemens Phase, Voltage Monitoring Relay, 3 Phase, DPDT, 160 → 690V ac, DIN Rail
Technical documents
Specifications
Brand
SiemensMonitoring Application
Phase, Voltage
Electrical Phase
3
Contact Configuration
DPDT
Voltage Sensing Range
160 → 690V ac
Voltage Sensitivity
Undervoltage
Mounting Type
DIN Rail
Phase Sensitivity
Phase Failure, Phase Imbalance, Phase Sequence
Time Delay
0.1 → 20s
Series
3UG4
Height
92mm
Standards Met
RoHS Compliant
Number of Poles
3
Dimensions
91 x 22.5 x 92mm
Length
91mm
Minimum Voltage Sensed
160V ac
Operating Temperature Range
+60°C
Terminal Type
Screw
Minimum Operating Temperature
-25°C
Width
22.5mm
Maximum Operating Temperature
+60°C
Maximum Voltage Sensed
690V ac
Country of Origin
Germany
Product details
Line Supply and Three Phase Voltage
3UG4 relays that monitor current, power factor and active current are ideal for monitoring the load of motors and functionality of electronic loads. These devices detect the effect of wear and faults early on. This means that appropriate actions can be taken before more significant damage occurs.
Wide voltage range versions reduce inventory stock levels
Variable settings for over-range, under-voltage or window monitoring
Delay times and reset switch
Actual value and fault types are permanently displayed
Removable terminals
22.5mm wide
3UG4614 to 3UG4617 can be digitally set, with fault memory and LDC display
1-20V hysterisis
Phase failure (except stock no 518-7275)
Stock information temporarily unavailable.
Please check again later.
€ 195.31
Each (ex VAT)
1
€ 195.31
Each (ex VAT)
1
Technical documents
Specifications
Brand
SiemensMonitoring Application
Phase, Voltage
Electrical Phase
3
Contact Configuration
DPDT
Voltage Sensing Range
160 → 690V ac
Voltage Sensitivity
Undervoltage
Mounting Type
DIN Rail
Phase Sensitivity
Phase Failure, Phase Imbalance, Phase Sequence
Time Delay
0.1 → 20s
Series
3UG4
Height
92mm
Standards Met
RoHS Compliant
Number of Poles
3
Dimensions
91 x 22.5 x 92mm
Length
91mm
Minimum Voltage Sensed
160V ac
Operating Temperature Range
+60°C
Terminal Type
Screw
Minimum Operating Temperature
-25°C
Width
22.5mm
Maximum Operating Temperature
+60°C
Maximum Voltage Sensed
690V ac
Country of Origin
Germany
Product details
Line Supply and Three Phase Voltage
3UG4 relays that monitor current, power factor and active current are ideal for monitoring the load of motors and functionality of electronic loads. These devices detect the effect of wear and faults early on. This means that appropriate actions can be taken before more significant damage occurs.
Wide voltage range versions reduce inventory stock levels
Variable settings for over-range, under-voltage or window monitoring
Delay times and reset switch
Actual value and fault types are permanently displayed
Removable terminals
22.5mm wide
3UG4614 to 3UG4617 can be digitally set, with fault memory and LDC display
1-20V hysterisis
Phase failure (except stock no 518-7275)