Technical documents
Specifications
Brand
MetrixAccessory Type
USB optical cable
For Use With
CA 6470N, CA 6471, CA 6550, CA 6555, OX5022B, OX5042B, MTX3291B, MTX3292B, MTX3292B-BT, MTX3293B, MTX3293B-BT
Country of Origin
France
Product details
MTX 3000 Series, Graphical Multimeters
High performance all in one multimeter for laboratory or on-site use.
Large (58x58mm) 160 x 160 dot matrix multi-directional LCD graphic screen with backlight.
Depending on the function selected results are displayed in several ways:
* 4 x 100,000 count digital displays for simultaneous display of associated measurements
* Mixed display mode combines a stable digital readout with bargraph display of indicating rapid variations and a graphic recorder displaying measurement variation over time
3 input terminals with automatically selected measurements,
Full autoranging current measurement utilising one current input terminal
Simultaneous current & voltage measurements can be made using 3 measurement leads
8-way keypad mimics a "virtual" measurement switch providing "one-hand one-touch" ergonomics
Configuration menu & on-line help
Data acquisition up to 4 measurements at once - interval from 1s to 24h
4x150 measurements storage
SPEC function displays the reading and measurement tolerances (min and max) for complete clarity of measurement uncertainties
SURV function: Surveillance and storage of "MIN", "MAX", and "AVG" values with time stamp
Manual hold of display (HOLD) or automatic hold on stable measurement (AUTOHOLD)
Frequency measurements up to 2 MHz, duration, cyclical ratio, events metering
10nF to 10mF capacitance ranges
Favourite measurement key assigned to any physical quantity (conversion & unit)
Dimensions and weight : 44 x 85 x 180 mm : 400 g.
Complies with IEC 61010-1 CAT IV 600V; CAT III 1000V
MTX3282 additional features
0.03% dcV basic accuracy; 100kHz bandwidth
AUTOPEAK mode provides fast autoranging for error-free measurements without crest factor limitations
MATH function applies a user defined mathematical scaling to a measured value for direct display.
Temperature measurement from J, K type thermocouples and PT100 / PT1000 probes
Pulse counting up to 99,999, minimum duration 5μs
Supplied with
Standard version: 3 AA alkaline batteries, test lead set & instructions
-COM version optical RS232 cable; SX-DIMM software; 3 AA NiMH rechargeable battery, test lead set & instructions, mains adaptor/charger
-BT version Bluetooth wireless link: SX-DMM software; 3 AA NiMH rechargeable battery, test lead set & instructions, mains adaptor/charger
Stock information temporarily unavailable.
Please check again later.
€ 164.27
Each (ex VAT)
1
€ 164.27
Each (ex VAT)
1
Technical documents
Specifications
Brand
MetrixAccessory Type
USB optical cable
For Use With
CA 6470N, CA 6471, CA 6550, CA 6555, OX5022B, OX5042B, MTX3291B, MTX3292B, MTX3292B-BT, MTX3293B, MTX3293B-BT
Country of Origin
France
Product details
MTX 3000 Series, Graphical Multimeters
High performance all in one multimeter for laboratory or on-site use.
Large (58x58mm) 160 x 160 dot matrix multi-directional LCD graphic screen with backlight.
Depending on the function selected results are displayed in several ways:
* 4 x 100,000 count digital displays for simultaneous display of associated measurements
* Mixed display mode combines a stable digital readout with bargraph display of indicating rapid variations and a graphic recorder displaying measurement variation over time
3 input terminals with automatically selected measurements,
Full autoranging current measurement utilising one current input terminal
Simultaneous current & voltage measurements can be made using 3 measurement leads
8-way keypad mimics a "virtual" measurement switch providing "one-hand one-touch" ergonomics
Configuration menu & on-line help
Data acquisition up to 4 measurements at once - interval from 1s to 24h
4x150 measurements storage
SPEC function displays the reading and measurement tolerances (min and max) for complete clarity of measurement uncertainties
SURV function: Surveillance and storage of "MIN", "MAX", and "AVG" values with time stamp
Manual hold of display (HOLD) or automatic hold on stable measurement (AUTOHOLD)
Frequency measurements up to 2 MHz, duration, cyclical ratio, events metering
10nF to 10mF capacitance ranges
Favourite measurement key assigned to any physical quantity (conversion & unit)
Dimensions and weight : 44 x 85 x 180 mm : 400 g.
Complies with IEC 61010-1 CAT IV 600V; CAT III 1000V
MTX3282 additional features
0.03% dcV basic accuracy; 100kHz bandwidth
AUTOPEAK mode provides fast autoranging for error-free measurements without crest factor limitations
MATH function applies a user defined mathematical scaling to a measured value for direct display.
Temperature measurement from J, K type thermocouples and PT100 / PT1000 probes
Pulse counting up to 99,999, minimum duration 5μs
Supplied with
Standard version: 3 AA alkaline batteries, test lead set & instructions
-COM version optical RS232 cable; SX-DIMM software; 3 AA NiMH rechargeable battery, test lead set & instructions, mains adaptor/charger
-BT version Bluetooth wireless link: SX-DMM software; 3 AA NiMH rechargeable battery, test lead set & instructions, mains adaptor/charger