Multifunction Testers
Multifunction testers or MFTs are handheld versatile devices used to verify the safety of electrical installations in domestic, commercial, and industrial settings. These installation testers are designed to streamline and simplify electrical testing processes and ensure that fixed wiring is safe and correctly installed to meet relevant local standards and safety requirements
Multifunctio...
Showing 1-20 of 129 products

RS Stock No.: 200-3705Brand: RS PRO
€ 63.60
€ 63.60 Each (ex VAT)
Check stock
1

RS Stock No.: 200-3704Brand: RS PRO
€ 26.27
€ 26.27 Each (ex VAT)
Check stock
1
RS Pro
-
-
No
-
-
-
-
48V
Auto Test
-
-
-
-
-
-
-
68g
12 V
-
Battery
86mm
-
-
-
-
-
28.5mm
LCD - Backlit
-
86 x 37 x 28.5mm
-
-
-
-
37mm
Hazardous Product

RS Stock No.: 144-5338Brand: RS PRO
€ 991.80
€ 991.80 Each (ex VAT)
Check stock
1
RS Pro
-
Phase to Earth
Yes
MT-6600
Yes
Yes
1000V
1000V
Multifunction Installation Tester
Yes
-
Bluetooth, WiFi
1mA
General, Selective
-
IP65
1.6kg
1.2 V AA Rechargeable Ni-MH, 1.5 V AA Alkaline
-
Battery
242mm
CAT III
+45°C
-
-
-
105mm
LCD
CAT III 600 V
242 x 105 x 145mm
2000Ω
0Ω
600V
0°C
145mm

RS Stock No.: 177-9342Brand: RS PRO
€ 1,300.32
€ 1,300.32 1 Kit (ex VAT)
Check stock
1
RS Pro
-
Phase to Earth
Yes
MT-6600
Yes
Yes
1000V
1000V
-
-
-
Bluetooth
1mA
-
-
IP67
1.6kg
-
-
Battery
242mm
CAT III
+45°C
-
-
-
105mm
LCD
CAT III 600V
242 x 105 x 145mm
2000Ω
0Ω
600V
0°C
145mm
Hazardous Product

RS Stock No.: 144-5350Brand: RS PRO
€ 1,126.55
€ 1,126.55 Each (ex VAT)
Check stock
1
RS Pro
RSCAL
Phase to Earth
Yes
-
Yes
Yes
1000V
1000V
Multifunction Installation Tester
Yes
-
Bluetooth
1mA
General, Selective
-
IP65
1.6kg
1.2 V AA Rechargeable Ni-MH, 1.5 V AA Alkaline
-
Battery
242mm
CAT III
+45°C
-
-
-
105mm
LCD
CAT III 600 V
242 x 105 x 145mm
2000Ω
0Ω
600V
0°C
145mm
Hazardous Product

RS Stock No.: 144-5351Brand: RS PRO
€ 1,193.92
€ 1,193.92 Each (ex VAT)
Check stock
1
RS Pro
UKAS
Phase to Earth
Yes
-
Yes
Yes
1000V
1000V
Multifunction Installation Tester
Yes
-
Bluetooth
1mA
General, Selective
-
IP65
1.6kg
1.2 V AA Rechargeable Ni-MH, 1.5 V AA Alkaline
-
Battery
242mm
CAT III
+45°C
-
-
-
105mm
LCD
CAT III 600 V
242 x 105 x 145mm
2000Ω
0Ω
600V
0°C
145mm
Fluke
-
3 Wire
-
1651B
-
Yes
250 V, 500 V, 1000 V
500V ac
Continuity, Wiring Polarity
-
-
UK Mains
200mA
AC Type
BS 7671, EN 61010-I, HD 384, IEC 60364
IP40
1.5kg
AA
Type F - Schuko plug, Type G - British 3-pin
Battery, Mains
100mm
CAT III, CAT IV
+40°C
-
-
-
250mm
LCD
CAT III 500 V, CAT IV 300 V
100 x 250 x 125mm
2000Ω
20Ω
300 V, 500 V
-10°C
125mm
Fluke
-
3 Wire
Yes
1653B
Yes
Yes
50 V, 100 V, 250 V, 500 V, 1000 V
500V ac
Continuity, Wiring Polarity
Yes
Yes
-
200mA
AC Type
EN 61010-I, HD 384, IEC 60364
IP40
1.3kg
AA
Type G - British 3-pin
Battery, Mains
100mm
CAT III, CAT IV
+40°C
-
-
-
250mm
LCD
CAT III 500 V, CAT IV 300 V
100 x 250 x 125mm
2000Ω
20Ω
300 V, 500 V
-10°C
125mm
Fluke
-
-
-
T6-600
-
-
-
600V ac
AC Current, AC Voltage, DC Voltage, Resistance
-
-
-
-
-
-
-
350g
AA IEC LR6
-
-
61.1mm
CAT III
+50°C
-
-
-
43.8mm
Digital
-
61.1 x 43.8 x 259.3mm
-
-
600V
-10°C
259.3mm
Fluke
-
-
Yes
T5
No
-
-
600V ac
AC Current, AC Voltage, Continuity, DC Current, DC Voltage, Resistance
-
-
-
-
-
-
-
300g
AA x 2
-
Battery
30.5mm
CAT III
+50°C
0 → 1000 O
0 to 600V
-10 → +50 °C
51mm
-
CAT III 600 VV
30.5 x 51 x 203mm
-
0Ω
600V
-10°C
203mm
Fluke
-
Phase to Earth, Phase to Neutral
Yes
1662
Yes
No
100 V, 250 V, 500 V, 1000 V
500V ac/dc
Continuity, Frequency, Insulation Resistance, Loop and Line Resistance, Measure Motor Windings, Phase Sequence Test, Prospective Earth Fault Current, Prospective Short Circuit Current, RCD Test, Resistance, Voltage, Wiring Polarity
-
Yes
-
10mA
A, AC
IEC 60364
IP40
1.3 (with Battery)kg
AA
UK
Battery
100mm
CAT III, CAT IV
-
-
100 → 1000V
-
250mm
-
CAT III 500 V, CAT IV 300 V
100 x 250 x 125mm
2000Ω
20Ω
300 V, 500 V
-
125mm
Kewtech Corporation
-
2 Wire, 3 Wire
Yes
KT65DL
Yes
Yes
100V
500V
Continuity
Yes
Yes
USB
200mA
AC Type
EN 61557, IEC 61557
IP40
1.4kg
AA, LR6
-
Battery
235mm
CAT III
+40°C
-
-
-
136mm
Backlight
CAT III 300 V
235 x 136 x 114mm
2000Ω
20Ω
300V
0°C
114mm
Martindale
-
-
-
ET4
-
-
-
600V ac
-
-
-
-
-
-
-
-
200g
9V
-
Battery
202.5mm
CAT III
+40°C
-
-
-
51mm
LCD
CAT III 600V
202.5 x 51 x 44mm
-
-
600V
0°C
44mm
Fluke
-
-
Yes
T5
No
-
-
1000V ac
AC Current, AC Voltage, Continuity, DC Current, DC Voltage, Resistance
-
-
-
-
-
-
-
300g
AA x 2
-
Battery
30.5mm
CAT III, CAT IV
+50°C
25 → 400 O
0 to 1000V
-10 → +50 °C
51mm
-
CAT IV 600 V / CAT III 1000 VV
30.5 x 51 x 203mm
1000Ω
0Ω
600 V, 1000 V
-10°C
203mm
Fluke
-
-
-
T5-600 + 62MAX + 1AC-II
-
-
-
600V ac
AC Current, AC Voltage, DC Voltage, Resistance
-
-
-
-
-
-
-
380g
AA
-
-
30.5mm
CAT III
+50°C
-
-
-
51mm
LCD
-
30.5 x 51 x 203mm
-
-
600V
-10°C
203mm
Fluke
-
Phase to Earth, Phase to Neutral
Yes
1664FC
Yes
-
50 V, 100 V, 250 V, 500 V, 1000 V
500V ac/dc
Continuity, Frequency, Insulation Resistance, Loop and Line Resistance, Measure Motor Windings, Phase Sequence Test, Prospective Earth Fault Current, Prospective Short Circuit Current, RCD Test, Resistance, Voltage, Wiring Polarity
Yes
Yes
BLE, USB
10mA
A/F, AC, B/B+, G, S
IEC 60364
IP40
1.3 (with Battery)kg
AA
UK
Battery
100mm
CAT III, CAT IV
-
-
50 → 1000V
-
250mm
-
CAT III 500 V, CAT IV 300 V
100 x 250 x 125mm
2000Ω
20Ω
300 V, 500 V
-
125mm
Martindale
-
-
-
ET5
-
-
-
600V ac
AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Resistance, Temperature
-
-
-
-
-
-
-
200g
9V
-
Battery
202.5mm
CAT III
+40°C
-
-
-
51mm
LCD
CAT III 600V
202.5 x 51 x 44mm
-
-
600V
0°C
44mm
...