Power Factor Correction Capacitors
The power factor of a circuit, for individual equipment or for a larger power supply, is the measure used to determine the efficiency of the circuit. It is calculated using the real power (kW) and reactive power (kVAr) of a circuit, with the real power being that which is actually used to complete the task at hand and the reactive power being that which does not contribute to the task. The high...
Showing 1-20 of 278 products
Schneider Electric
Power Factor Correction Capacitor
400 V ac
-
4 kV 50 Hz 1 minute
37kg
IEC 60068
-
-
-
-5 5 %
-
100kvar
-
-
PowerLogic
-
-
350mm
-
220 mm
-
-
0°C
-
-
-
-
-
-
350mm
55°C
Pad Terminal
-
-
-
Schneider Electric
Power Factor Correction Capacitor
400 V ac
-
-
9kg
IEC 60068, RoHS, REACH
-
-
-
-5 to 5 %
12.5kvar
-
-
-
SAH
-
-
-
-
240 mm
-
-
0°C
-
-
-
-
-
-
220mm
55°C
Pad Terminal
-
-
-
Schneider Electric
Power Factor Correction Capacitor
480 V ac
-
-
13kg
RoHS, REACH, IEC 60068
-
-
-
-5 5 %
12.5kvar
-
-
-
SAH
-
-
-
-
240 mm
-
-
0°C
-
-
-
-
-
-
220mm
55°C
Pad Terminal
-
-
-
Schneider Electric
Power Factor Correction Capacitor
400 V ac
-
-
131kg
IEC 61439-2, IEC 61921, IEC 61439-1
-
3
-
-5 to 10 %
125kvar
125kvar
-
-
PowerLogic
-
-
300mm
-
800 mm
-
Floor Standing
-5°C
-
-
-
-
-
-
1200mm
45°C
-
-
-
-
Schneider Electric
Power Factor Correction Capacitor
400 V ac
-
-
350kg
IEC 61921, IEC 61439-1, IEC 61439-2
-
3
-
-5 to 10 %
125kvar
125kvar
-
-
PowerLogic
-
-
600mm
-
800 mm
-
Floor Standing
-5°C
-
-
-
-
-
-
1400mm
45°C
-
-
-
-
Schneider Electric
Power Factor Correction Capacitor
400 V ac
-
-
131kg
IEC 61921, IEC 61439-1, IEC 61439-2
-
3
-
-5 to 10 %
150kvar
150kvar
-
-
PowerLogic
-
-
300mm
-
800 mm
-
Floor Standing
-5°C
-
-
-
-
-
-
1200mm
45°C
-
-
-
-
Schneider Electric
Power Factor Correction Capacitor
400 V ac
-
-
350kg
IEC 61921, IEC 61439-1, IEC 61439-2
-
3
-
-5 to 10 %
175kvar
175kvar
-
-
PowerLogic
-
-
600mm
-
800 mm
-
Floor Standing
-5°C
-
-
-
-
-
-
1400mm
45°C
-
-
-
-
Schneider Electric
Power Factor Correction Capacitor
400 V ac
-
-
131kg
IEC 61921, IEC 61439-1, IEC 61439-2
-
3
-
-5 to 10 %
175kvar
175kvar
-
-
PowerLogic
-
-
300mm
-
800 mm
-
Floor Standing
-5°C
-
-
-
-
-
-
1200mm
45°C
-
-
-
-
Schneider Electric
Power Factor Correction Capacitor
400 V ac
-
-
350kg
IEC 61921, IEC 61439-2, IEC 61439-1
-
3
-
-5 to 10 %
200kvar
200kvar
-
-
PowerLogic
-
-
600mm
-
800 mm
-
Floor Standing
-5°C
-
-
-
-
-
-
1400mm
45°C
-
-
-
-
Schneider Electric
Power Factor Correction Capacitor
400 V ac
-
-
400kg
CE, EAC, IEC 61439-1, ASEFA, IEC 61439-2, IEC 61921
-
3
-
-5% to 10%
225kvar
225kvar
-
-
PowerLogic
-
-
600mm
-
800 mm
-
-
-5°C
-
-
-
-
-
-
2000mm
45°C
-
-
-
-
Schneider Electric
Power Factor Correction Capacitor
400 V ac
-
-
175kg
IEC 61439-2, IEC 61439-1, IEC 61921
-
3
-
-5 to 10 %
238kvar
238kvar
-
-
PowerLogic
-
-
300mm
-
1000 mm
-
Floor Standing
-5°C
-
-
-
-
-
-
1200mm
45°C
-
-
-
-
Schneider Electric
Power Factor Correction Capacitor
400 V ac
-
-
17kg
RoHS, REACH, IEC 60068
-
-
-
-5 to 5 %
25kvar
-
-
-
SAH
-
-
-
-
240 mm
-
-
0°C
-
-
-
-
-
-
220mm
55°C
Pad Terminal
-
-
-
Schneider Electric
Power Factor Correction Capacitor
400 V ac
-
4 kV 50 Hz 1 minute
22kg
IEC 60068
-
-
-
-5 5 %
-
25kvar
-
-
PowerLogic
-
-
240mm
-
160 mm
-
-
0°C
-
-
-
-
-
-
220mm
55°C
Pad Terminal
-
-
-
Schneider Electric
Power Factor Correction Capacitor
400 V ac
-
-
14.5kg
RoHS, IEC 60068, REACH
-
-
-
-5 to 5 %
25kvar
-
-
-
SAH
-
-
-
-
240 mm
-
-
0°C
-
-
-
-
-
-
220mm
55°C
Pad Terminal
-
-
-
Schneider Electric
Power Factor Correction Capacitor
400 V ac
-
-
18kg
RoHS, REACH, IEC 60068
-
-
-
-5 to 5 %
25kvar
-
-
-
SAH
-
-
-
-
240 mm
-
-
0°C
-
-
-
-
-
-
220mm
55°C
Pad Terminal
-
-
-
Schneider Electric
Power Factor Correction Capacitor
220 V ac
-
-
17.5kg
REACH, IEC 60068, RoHS
-
-
-
-5 to 5 %
25kvar
-
-
-
SAH
-
-
-
-
240 mm
-
-
0°C
-
-
-
-
-
-
220mm
55°C
Pad Terminal
-
-
-
Schneider Electric
Power Factor Correction Capacitor
480 V ac
-
-
17.5kg
RoHS, REACH, IEC 60068
-
-
-
-5 to 5 %
25kvar
-
-
-
SAH
-
-
-
-
240 mm
-
-
0°C
-
-
-
-
-
-
220mm
55°C
Pad Terminal
-
-
-
Schneider Electric
Power Factor Correction Capacitor
400 V ac
-
-
400kg
IEC 61921, IEC 61439-2, CE, EAC, ASEFA, IEC 61439-1
-
3
-
-5 to 10 %
250kvar
250kvar
-
-
PowerLogic
-
-
600mm
-
800 mm
-
Floor Standing
-5°C
-
-
-
-
-
-
2000mm
45°C
-
-
-
-
Schneider Electric
Power Factor Correction Capacitor
400 V ac
-
-
400kg
IEC 61921, IEC 61439-2, IEC 61439-1
-
3
-
-5 to 10 %
250kvar
250kvar
-
-
PowerLogic
-
-
600mm
-
800 mm
-
Floor Standing
-5°C
-
-
-
-
-
-
2000mm
45°C
-
-
-
-
Schneider Electric
Power Factor Correction Capacitor
400 V ac
-
PowerLogic PFC Capacitor
175kg
CE, IEC 61921, IEC 61439-2, ASEFA, IEC 61439-1, EAC
-
3
-
-5 to 10 %
250kvar
250kvar
-
-
PowerLogic
-
-
300mm
-
1000 mm
-
Floor Standing
-5°C
-
-
-
-
-
-
1200mm
45°C
-
-
-
-
...