Technical documents
Specifications
Brand
MeggerAbsolute Maximum AC Current Measurement
300A ac
Model Number
DCM300E
Calibrated
RSCAL
AC Current Measurement Resolution
10µA
Clamp Meter Type
Leakage Clamp Meter
Best AC Current Accuracy
±5% +5 digits
Functions Measured
AC Current
True RMS
No
Jaw Capacity Busbars
32mm
Power Source
Battery
Width
64mm
Length
23mm
Dimensions
23 x 64 x 176mm
Minimum Operating Temperature
0°C
Height
176mm
AC Current Measurement Range
0 → 300 A
Battery Life
50 h
Weight
125g
Safety Category Level
CAT II, CAT III
Safety Category Voltage
500 V, 600V
Battery Type
LR44
Safety Category
CAT II 600 V, CAT III 500V
Display Type
LCD
Maximum Operating Temperature
+40°C
Country of Origin
Japan
Product details
AVO DCM 300E
Fully IEC1010-1 and IEC101-2-032 compliant for circuits up to 500V phase to phase or 300V phase to earth CAT III or 600V CAT II
30mA and 300mA ranges for leakage current measurement
0.01mA resolution on 30mA range
30A and 300A ranges for power measurements
Data hold facility
Maximum conductor size 40mm diameter
3200 count LCD display with analogue bar graph
Supplied with
Batteries, instruction manual, carrying case.
Stock information temporarily unavailable.
Please check again later.
£ 808.65
Each (ex VAT)
1
£ 808.65
Each (ex VAT)
1
Technical documents
Specifications
Brand
MeggerAbsolute Maximum AC Current Measurement
300A ac
Model Number
DCM300E
Calibrated
RSCAL
AC Current Measurement Resolution
10µA
Clamp Meter Type
Leakage Clamp Meter
Best AC Current Accuracy
±5% +5 digits
Functions Measured
AC Current
True RMS
No
Jaw Capacity Busbars
32mm
Power Source
Battery
Width
64mm
Length
23mm
Dimensions
23 x 64 x 176mm
Minimum Operating Temperature
0°C
Height
176mm
AC Current Measurement Range
0 → 300 A
Battery Life
50 h
Weight
125g
Safety Category Level
CAT II, CAT III
Safety Category Voltage
500 V, 600V
Battery Type
LR44
Safety Category
CAT II 600 V, CAT III 500V
Display Type
LCD
Maximum Operating Temperature
+40°C
Country of Origin
Japan
Product details
AVO DCM 300E
Fully IEC1010-1 and IEC101-2-032 compliant for circuits up to 500V phase to phase or 300V phase to earth CAT III or 600V CAT II
30mA and 300mA ranges for leakage current measurement
0.01mA resolution on 30mA range
30A and 300A ranges for power measurements
Data hold facility
Maximum conductor size 40mm diameter
3200 count LCD display with analogue bar graph
Supplied with
Batteries, instruction manual, carrying case.